HED Group - We are proud to supply RO ESPA2 MAX membranes from Nitto Denko/ Hydranautics, the manufacturer, in Vietnam.
| Permeate Flow: | 12,000 gpd (45.4 m3 /d) |
| Salt Rejection: | 99.6% (99.5% minimum) |
| Test Conditions: | 1,500 ppm NaCl solution |
| 150 psig (1.03 MPa) Applied Pressure | |
| 77 °F (25 °C) Operating Temperature | |
| 15% Permeate Recovery | |
| 6.5 - 7.0 pH Range |
The Specified Performance is based on data taken after a minimum of 10 minutes of operation. Actual testing of elements may be done at conditions which vary from these exact values; in which case, the performance is normalized back to these standard conditions. Permeate flow for individual elements may vary ±15 percent from the value specified.

| Configuration: | Spiral Wound |
| Membrane Polymer: | Composite Polyamide |
| Membrane Active Area**: | 440 ft2 (40.9 m2 ) |
Packaging: All membrane elements are supplied with a brine seal, interconnector, and O-rings. Elements are enclosed in a sealed polyethylene bag containing less than 1.0% sodium meta-bisulfite solution, and then packaged in a cardboard box.

| Maximum Applied Pressure: | 600 psig (4.14 MPa) |
| Maximum Chlorine Concentration: | < 0.1 ppm |
| Maximum Operating Temperature: | 113 °F (45 °C) |
| pH Range, Continuous (Cleaning): | 2-10.6 (1 -12) |
| Maximum Feedwater Turbidity: | 1.0 NTU |
| Maximum Feedwater SDI (15 mins): | 5.0 |
| Maximum Feed Flow: | 75 gpm (17.0 m3/h) |
| Minimum Brine Flow: | 12 gpm (2.7 m3/h) |
| Maximum Pressure Drop for Each Element: | 15 psi (0.10 MPa) |